How to Evaluate ECG-to-PPG Embedding Transfer Without Data Leakage

2026-11-03

A model trained on chest ECG sees the timing of electrical depolarisation. A wrist photoplethysmogram (PPG) sees changes in peripheral blood volume. Both can yield an estimate of successive cardiac cycles, but a column called signal_value would not mean the same thing in the two datasets. If an ECG embedding works on PPG, what exactly has transferred: a representation of cardiovascular dynamics, a shared preprocessing artifact, or a shortcut tied to the people and recording protocol?

This tutorial answers a narrow question: how can an engineer test whether a sequence representation learned from one sensor type is useful on another sensor type with related but non-identical channels? The answer starts with a common measurement contract, then separates three tests that are often collapsed into one: input compatibility, downstream utility, and robustness on a genuinely held-out device and population. The worked example is synthetic and specifies an experiment; it reports no model performance.

Decide what “portable” means before training

Portability has at least three levels. Mechanical portability means that the target device can produce the source model’s required input columns, units, sampling cadence, missingness indicators, and categorical encodings. It says nothing about predictive quality. Statistical portability means that a frozen source encoder’s outputs retain useful structure on the target device, under a prespecified comparison. Task portability means that a downstream model built on those outputs performs acceptably on the target device for a specified task and population.

These levels need different evidence. A script that maps PPG pulse intervals into a column named cycle_interval_ms establishes a plausible input interface. A plot of source and target embeddings mixed together might suggest distributional similarity, but can hide loss of task information. A strong target test score can also be misleading if participant identity, exercise schedule, or data collected after the prediction point leaked into the probe. The operational claim should therefore be as specific as “a frozen ECG-trained encoder improves a rest-versus-step-up classifier on held-out PPG participants, given a fixed amount of PPG labels,” rather than “the model understands physiology.”

This is an empirical question, not an architectural property. The BIOT biosignal paper explicitly addresses mismatched channels and other format differences; that research motivation does not establish transfer for a different model or task. A study of cross-device ECG models found that movement from clinical systems to home devices could degrade accuracy despite apparently related waveforms. Even before changing modality, device shift deserves measurement.

How this protocol relates to ECG–PPG research

The research question is established, but the method here is deliberately smaller than a new cross-modal architecture. CardioFM is a 2026 preprint describing joint ECG/PPG representation learning with modality-specific waveform processing and cross-modal attention. xMAE uses masked cross-modal reconstruction and the temporal relationship between electrical activation and the delayed peripheral pulse. Earlier ECG-to-PPG sleep-staging work directly compared ECG-pretrained transfer with PPG training and adaptation. These studies show why the transfer question matters and offer architectural alternatives when paired waveforms are available. They do not answer whether this frozen, source-only encoder on a common tabular feature contract improves this target task under matched windows and label budgets. The contribution here is a practical evaluation protocol for that narrower claim.

Build a toy measurement contract

Assume two hypothetical devices record the same supervised exercise protocol at the same time. Device A records one chest ECG lead and a three-axis accelerometer. Device B records wrist PPG and a three-axis accelerometer. The intended downstream task is to classify a completed two-minute segment as rest or paced step-up, using the independently logged protocol phase as its label. This is a laboratory task for testing transfer. It is not a medical diagnosis or evidence of exercise intensity in free living conditions.

The devices share some biological information, but their channels are not interchangeable:

Measurement Chest ECG adapter Wrist PPG adapter Common interpretation and caveat
Cardiac-cycle timing Detect R peaks and calculate successive R–R intervals Detect pulse peaks and calculate successive pulse intervals A time between detected cycles, in milliseconds; ectopic beats, missed peaks, and motion can distort either estimate differently.
Segment motion Convert acceleration to a declared motion summary Apply the same definition after calibrating the accelerometer axes and magnitude Nuisance and task information; placement changes its distribution.
Availability Fraction of short signal-quality epochs accepted for ECG analysis Fraction accepted for PPG analysis A detector-dependent coverage measure, not an interchangeable physiological signal.
Raw morphology ECG amplitude and QRS shape Optical pulse shape and amplitude Keep separate. Giving both the same column name would make a false semantic claim.

The common table should contain only features whose interpretation can be defended on both devices. Choose non-overlapping 30-second bins, in a specified clock and timezone, and make one row per bin. cycle_interval_ms is the median accepted interval whose ending peak falls in the bin. interval_spread_ms is a robust within-bin spread of those accepted intervals. motion_rms is the root-mean-square acceleration magnitude after a declared gravity-removal step. valid_fraction is the fraction of one-second epochs that pass a prespecified, modality-specific signal-quality rule. seconds_since_last_valid makes an outage distinguishable from a stable interval. These definitions are design choices for the toy study, not universal physiological feature standards.

Here is a three-row illustration of the harmonised table. The numbers are invented and are not observations or model output:

sequenceId itemPosition cycle_interval_ms interval_spread_ms motion_rms valid_fraction seconds_since_last_valid
101 0 842 34 0.06 0.96 0
101 1 805 42 0.10 0.89 0
101 2 null null 0.67 0.11 28

Row 2 is an important case. Filling the missing cycle interval with zero, or with a source-device mean while hiding the missingness, would turn an acquisition failure into an invented physiological measurement. A real pipeline must define a fill value or masking scheme compatible with the model and preserve the availability feature. The Sequifier preprocessing guide documents row-level masking and numeric preprocessing; it does not make arbitrary per-feature missing values safe by itself. For this proposed experiment, one conservative policy is to exclude assessment windows containing bins below a prespecified coverage threshold from both devices, count those exclusions, and test an alternative imputation-plus-availability policy separately. This avoids creating artificial gaps in the sequence and silently changing the target population when PPG is noisier during movement.

The table needs a separate audit manifest. Keep participant ID, session ID, device model, firmware, body placement, recorded sample rate, clock-offset estimate, signal-processing version, bin start and end time, and exclusion reason outside the model input unless a particular ablation deliberately includes them. Use a unique sequenceId for each participant-session-device stream; itemPosition is an integer bin order within that stream. The feature table above is the proposed model interface, while the manifest makes the interface auditable. Sequifier’s documented tabular input requires sequenceId, itemPosition, and one or more feature columns in its README.

Check the adapters before asking a model to repair them

On paired recordings, first compare the two devices’ interval estimates under clean rest, movement, and low coverage. Report bias, spread of paired differences, and the fraction of bins for which each adapter produces an interval. Two devices can agree on the average rate while disagreeing on beat timing or missingness. The published multi-device synchronisation and validation study illustrates why agreement should be checked at both waveform and derived-feature levels. A separate wearable heart-rate assessment guide identifies hardware, firmware, algorithms, and sampling rate as sources of variation worth recording.

Do not learn a time shift or calibration from the final test participants. Estimate clock offsets on dedicated synchronisation events or on training recordings under a locked rule. When only one device is available at inference, the adapter must work without consulting the missing device. If the paired comparison shows that cycle_interval_ms has unacceptable bias during movement, the portability experiment should stop at the input-contract gate or narrow to a clean-coverage population. An embedding cannot make two incorrectly aligned measurements semantically identical.

For any paired-device agreement or embedding comparison, form a single assessment-window manifest first. A row is eligible only when both devices cover the identical participant, session, UTC start and end time, twenty-bin context, and completed two-minute label interval under the declared quality rule. Intersect the ECG and PPG eligibility flags, then compute both devices’ scores on that same set of manifest rows. Report each device’s excluded count and the intersection count. The separate full-population PPG analysis may include its additional eligible windows, but its denominator and question must be named separately. Otherwise a seemingly paired difference can be driven by comparing clean ECG rest periods with a different set of PPG movement periods.

Choose a source objective that can be evaluated on the target

Train the source sequence model on Device A’s harmonised rows. A possible causal pretraining objective predicts the next bin’s cycle interval and coverage from the previous bins. A context of twenty 30-second rows represents ten minutes of history; that number is a hypothesis to compare with shorter contexts, not a recommended physiological constant. The same feature names, units, bin definitions, and preprocessing metadata are then used to extract embeddings from Device B. Keep raw ECG morphology out of this first model because Device B has no honest mapping for it.

The objective shapes the embedding. Predicting the next interval rewards short-term rhythm and activity context. It may fail to preserve waveform properties relevant to other tasks, and next-bin coverage prediction can reward learning device-specific artifact patterns. If the intended downstream task needs morphology, the common interval schema is insufficient; either design modality-specific encoders with an explicit alignment objective or accept that a shared frozen encoder is the wrong test. Equally, a model trained only on the synthetic protocol is simply a pretrained sequence model for that experiment, not a demonstrated physiological foundation model.

Other approaches deserve a place in the comparison. A handful of summaries—median interval, interval spread, motion, coverage—may let a regularised logistic model or a tree model classify the activity phase well. A one-dimensional convolution or recurrent model can use ordered bins with less machinery than a transformer. A device-specific model trained on available PPG labels measures the value of local training. If the simple common-feature baseline already meets the task’s target-device requirement, there is no reason to require a transferable embedding for this use case.

Trace one decision through the toy sequence

Suppose a session has thirty 30-second bins, numbered 0 through 29. For an assessment ending at bin 19, the twenty-row source or target input is bins 0–19. The encoder output associated with the last input position is the candidate representation of that history. The protocol log supplies the label for the completed two-minute interval covered by bins 16–19. Bin 20 is a legitimate future target for causal pretraining, but must never enter the embedding or a feature computed for the assessment at bin 19. If bin 18 lacks a valid pulse interval, the declared policy either excludes this assessment or supplies the permitted missing-value representation together with the availability fields. It must do the same on the source and target sides.

This small accounting exercise catches three common errors. First, an average across bins 16–20 looks like a harmless smoothing operation, but it includes a future bin. Second, using the target device’s full-session mean to standardise bins 0–19 allows later recording conditions to affect an earlier prediction. Third, a train/test split of the thirty rows could place almost identical twenty-row histories on both sides. Split the participant before making any windows, then assign the completed segment label to the allowed window endpoint. Each resulting probe example should retain the participant, session, device, endpoint timestamp, and source row range in the audit table so that these checks can be performed programmatically.

Sequifier’s embedding output needs an explicit join rule. For a proposed non-aligned causal inference view with one exported position, an embedding from input bins 0–19 is labeled by input activation itemPosition = 19. Its output also carries sequenceId, subsequenceId, and windowStartOffset. Resolve that sequenceId through the device-specific audit manifest, retain the selected window identifiers, and join to the externally logged completed-segment label on (participant, session, device, endpoint itemPosition = 19). The label’s interval is bins 16–19. Assert that the resolved input history ends at 19 and that each assessment key has exactly one selected embedding; do not silently take the first of overlapping windows. This describes an intended extraction and join, not a tested configuration.

There is an important alternate convention. For a prediction-aligned split with causal target_offset: 1, the preprocessing guide and inference guide say that the same causal context ending at input 19 is labeled by its target itemPosition = 20. In that case derive endpoint itemPosition = exported itemPosition - 1 before joining to the completed-segment label at 19. Check this mapping against a tiny known sequence and verify the actual output rows before running the probe. Joining aligned output position 20 directly to the label for a segment ending at 20 would introduce an off-by-one error and potentially use the wrong assessment.

The choice of target matters, too. A next-interval objective can be inspected on both devices without protocol labels, but success at that objective is only a pretraining diagnostic. The downstream phase label asks a different question. If the encoder predicts next intervals well while the frozen probe adds nothing over motion and current interval, the experiment has found a useful forecasting representation for one task, not a transferable improvement for the proposed classification task. Conversely, if the probe improves on the target device only after substantial PPG adaptation, report adaptation as part of the method and its data budget.

Run the transfer test as a small factorial experiment

The decisive contrast is not “source encoder versus nothing.” Hold the target task, PPG labels, target participants, and evaluation set fixed; vary only the representation or adaptation strategy. A practical matrix is:

Arm What is fitted before target-task training? What is fitted on labeled PPG training participants? Question answered
A: common-feature baseline The declared ECG and PPG adapters Logistic or tree model on PPG summaries How far can engineered features get?
B: source-trained baseline A classifier on ECG summaries and ECG protocol labels Nothing Do simple decision rules transfer directly?
C: frozen source embedding Causal encoder on unlabeled ECG sequences Regularised linear probe on PPG embeddings Do ECG representations reduce target label needs?
D: target-only embedding Same architecture pretrained on unlabeled PPG sequences Same probe, same PPG labels Is source pretraining better than local pretraining?
E: adapted source embedding ECG pretrained encoder Limited PPG adaptation plus the probe Does target adaptation buy enough to justify its cost?

For arm C, the encoder and its preprocessing metadata are frozen. Fit the probe using, for example, 10, 50, and all eligible labeled target participants, with the same participant subsets for every arm. In arm E, spell out which weights are updated and include all additional PPG data in the cost comparison. Never call an arm “zero shot” if its normaliser, probe, threshold, or encoder has been fitted on target data. Conversely, applying a frozen encoder to a target dataset using a new target mean and variance is an adaptation step, even if no neural weights change.

Arms C and D also need a comparable unlabeled pretraining budget. In the primary comparison, use the intersection of eligible paired windows from training participants so that both encoders see the same participant-hours and window endpoints through their respective adapters. Match context length, optimisation steps, model capacity, and selection rule; report the valid windows and excluded hours for each modality before intersection, since equal clock time can produce unequal usable data. Keep labels for the target probe identical across arms. A secondary, realistic comparison can use all available ECG pretraining data against scarce PPG data, but publish those differing hours, participants, and training compute as part of the treatment. A gain in that arm could be a data-volume effect, not evidence that ECG is intrinsically a better source modality.

At minimum, add two ablations. First, remove motion: if transfer disappears, the model may have learned mainly movement rather than a portable cardiac representation. Second, remove or standardise coverage information: if an apparent gain changes sharply, acquisition quality may be driving the result. These ablations are diagnostic, not automatic grounds for exclusion. Motion may be a legitimate input for activity classification; the point is to know what carries the signal. A probe trained to predict device identity from embeddings is another useful diagnostic. Strong device separability does not by itself disprove useful transfer, but it warns against treating a mixed embedding plot as proof of invariance.

Keep people, sessions, and time on the right side of the split

Construct participant partitions before producing overlapping model windows. If repeated sessions exist, put all sessions from one participant on the same side of the split. Train source pretraining and choose all design settings without seeing held-out target participants. Within target PPG data, use a development partition for model selection and one untouched participant partition for the final estimate. If the intended claim is portability to an unseen device model, reserve that model entirely for a separate test; testing the same PPG hardware on new people answers a narrower question.

The paired design helps diagnose sensor effects but creates leakage opportunities. ECG and PPG windows recorded simultaneously from one participant must not end up in opposite participant partitions. Multiple adjacent 30-second bins from a two-minute segment are correlated; count participants and segments, not just windows. Avoid using protocol schedule, file naming, or the absolute bin number as a hidden task label. Align each embedding to the end of the input history and ensure that a causal representation for a segment never includes data collected after the segment’s decision time. The Sequifier inference guide notes that aligned embeddings may be labeled by the target row rather than the input activation position; that distinction matters when joining embeddings to labels.

Fit scaling, imputation values, categorical maps, beat-detection thresholds chosen from data, and probe coefficients only within the permitted training partition. Preserve a copy of the source metadata when applying the source encoder to PPG. The preprocessing guide supports a preexisting metadata configuration and says numeric statistics normally come from the training split. A compatibility check should confirm that every column, unit, type, and normalization statistic matches the frozen source model’s contract. A model that silently renormalises PPG using the target test distribution has changed the treatment being evaluated.

Score utility, coverage, and uncertainty together

For the synthetic rest-versus-step-up task, report balanced accuracy, sensitivity and specificity by phase, and calibration if the probe’s probabilities will be used. Give the confusion matrix and class prevalence on each device. Because many windows belong to one person, use participant-level uncertainty estimates, such as a bootstrap resampling participants, rather than pretending every bin is independent. Prespecify the primary comparison—say, arm C minus arm A at 50 labeled PPG participants—and the smallest improvement that would change an engineering decision. Repeatedly picking the best label budget after viewing test results would turn the test set into development data.

Coverage is part of performance. Report what fraction of raw recording time survives the detector and quality policy for ECG and PPG, separately by phase and participant. A model that scores well after removing most moving wrist segments has not solved the intended task. When target coverage differs from source coverage, show both a common high-quality subset comparison and a full-population analysis with a declared missingness policy. Interpret them as different estimands: performance on clean paired data versus performance over the intended deployment stream.

Finally, show a paired-device diagnostic on participants for whom both streams exist: compare embeddings or probe scores for simultaneous segments after accounting for the labels. A high correlation can be useful evidence of agreement, but is not sufficient: both encoders might simply track exercise phase or participant identity. Downstream score, failure cases, and coverage remain the primary tests. The result could reasonably be that source pretraining helps only with very few PPG labels, or only during clean rest. Such a qualified outcome is more informative than a single pooled transfer score.

Where Sequifier fits in the workflow

Sequifier is a candidate for the sequence-model arm, after the two adapters and the evaluation manifest have been fixed. Its README describes multivariate tabular sequences and the preprocess, train, and infer workflow. The preprocessing guide documents selected real and categorical columns, fixed-length windows, train/validation/test splitting, and reuse of preprocessing metadata. The training guide documents causal training and an export_embedding_model option. The inference guide documents model_type: embedding and embedding output with sequence and window identifiers. These capabilities support an ECG pretraining run followed by PPG embedding extraction under an explicitly shared schema.

The adapter work remains outside Sequifier: peak detection, clock synchronisation, modality-specific signal-quality assessment, and feature agreement audits. So does the downstream probe and participant-level transfer analysis. The article’s table is a proposed input contract, not a tested Sequifier configuration; actual training and inference files must be checked against the current guides and validated on the chosen data. In particular, the encoder cannot accept a missing ECG waveform field merely because the target is another physiological sensor. A more ambitious multi-interface or cross-modal alignment experiment would need its own contract and validation.

If the common-feature baselines leave a meaningful gap and the frozen source embedding closes it on held-out participants and device hardware, the next step is a prospective evaluation of the actual intended task. If they do not, the work still identifies where the transfer claim fails: channel semantics, measurement agreement, label availability, or model utility. For broader discussion of representation choice, Shaping the problem examines what a model is allowed to observe; choosing context length covers a separate sequence-design decision. Engineers who want to implement the verified sequence-model arm can star Sequifier on GitHub and inspect its current guides before building the experiment.